The Propex Malaga 5 Water Storage Heater, This high capacity water storage heater is standard with an efficient gas burner and the additional benefit of a 750 watt electric heating element. This can provide a quick and efficient supply of hot water for showering and washing in touring and motor caravans. The heater may also be installed in boats used exclusively on inland waterways i.e. Class 1 & 2 and subject to finding a satisfactory mounting position.
When used with the adapter plate the Malaga makes an excellent replacement for the Carver Cascade originally fitted to many caravans as well its far east copy the Henry Water Heater.
Features
Micro-processor Controller Electronics
The Malaga 5 water heater is equipped with the latest Propex electronics for accurate digital control of the heater operation and safety functions. The switch panel features 2 on/off switches for independently selecting either “gas only” or “230v only” or both. The Green L.E.D. on the switch panel lets you know when the gas burner is operating and also, by flashing a certain amount of times, the Red LED indicates various fault conditions.
Technical Data
Dimensions
Overall H 250mm W 325mm D 445mm
Weight Empty 9.3kg
Tank Capacity 13 litres
Water Temperature Thermostat Setting 70 °C
Overheat Thermostat Setting 90 °C
Water Supply
The heater will operate satisfactorily on either a system where the pump is controlled by the tap microswitches or the one controlled by a pressure switch. It must not be connect to mains water supply. Water connections can be provided to suit a range of standard fittings. Reinforced or semi rigid pipe must be used.
Pressure Relief Valve Settings 3 bar
Maximum Working Pressure 2 bar
Maximum Working Supply Pressure 1.9 bar
Gas Supply
Heat Input 1.15kw 84g/h
Pressure Settings: Propane 37mbar, Butane 28mbar, Mixtures 30mbar
Injector Bray 960/40
Electrical Supply 12v DC
Gas Connection 8mm O.D.
Mains Electricity Supply: 220/240vAC 50Hz Fused 5A
Safety and Quality
The Malaga E heater have been tested and comply with the following: 90/396/EEC gas appliance directive. 89/336/EEC EMC directive. 73/23EEC low voltage directive. It is manufactured under ISO 9001:2000 plus annex 11.3 gas directives 90/396EEC.
Installation Requirements
The heater should be floor mounted or suitably supported, normally in the bed box.
The flue is designed to pass through a vertical section of the caravan wall, structural sections of which should not be damaged.
The flue terminal position should not be closer than 300mm below an opening window or 600mm from a vertical corner.
Clearances required for installation and servicing: as seen from inside the caravan.
Clearances
LHS 240mm RHS 5mm
Rear 100mm Top 5mm